Systxccitc01 b has been discontinued - Dec 10, 2018 · I'm a newbie to this site. I've the latest Carrier Infinity WiFi thermostat SYSTXCCITC01-B installed in March of this year. I'm having trouble with connection to the Myinfinity server. My wifi connection is fine and it works with everything else in the house with the exception of the intermittent connection with the MyInfinity server.

 
Jan 10, 2021 · All but one device: Carrier Infinity Touch Thermostat (Model SYSTXCCITC01-A). This is an older smart thermostat that's been installed at my home for just over four years. I had no problems connecting the thermostat wirelessly to my old Orbi RBK50 system over the past year, but it would not connect to the RBK852. . Avatar the way of water showtimes near celebration cinema rivertown

SYSTXCCITC01---B Infinityr System Control Owner’s Manual A170203 NOTE: Read the entire instruction manual before starting the installation. The features and functions outlined in this Owner’s Manual reflect Version 1.3 or later software. Occupancy sensing is only available with Series B Infinity System Controls. Jan 8, 2023 · Carrier thermostat won’t turn on. If your thermostat has a blank screen, it’s likely due to a power issue. Check your electrical box and reset the circuit breaker. If you have a fuse box and the fuse has blown, replace it. Check the switches connected to your thermostat, furnace, and air conditioner. If you can pinpoint the issue to a ... • When you have completed all of the settings touch SAVE. 3.1.2. Setup Time Zone The time zone can be selected by selecting the set time zone from the menu. Then select the time zone for the location. Time zones for both US and Canada are included. 3.1.3. Enable Time Synchronization After setting up the time zone, the time synchronization can ...Our ten year-old Infinity SYSTXCC Controller (for running a dual stage Heat Pump/Furnace system) has failed, and according to our service guy, it cannot be repaired. In 2008 when we bought it, the warranty was a measly 5 years with no option to extend it via registration. Carrier won't do anything for us, so we're SOL.I have a SYSTXCCUID01-B Version 14 Carrier Infinity System Thermostat that is malfunctioning and read you recommended the SYSTXCCITC01-B as a compatible replacement from supplyhouse.com. My question i … read moreView and Download Carrier Infinity SYSTXCCITC01-C installation instructions manual online. Infinity SYSTXCCITC01-C thermostat pdf manual download. Also for: Infinity systxccwic01-b, Infinity systxccicf01-b, Infinity systxccwif01-b, A210174, A170203a, A180218c.Carrier SYSTXCCITC01-B - Infinity System Control - 7 Day Programmable w/ Touch-N-Go- <b>Note: This item requires a "G" terminal that was not available on units prior to 2008 Infinity Models.</b><br><br> The Infinity® System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface. With wireless connectivity, occupancy ...These systems have a feature called TrueSense filt er detection. This feature reads the change in static pressure caused by the filter accumulating di rt. At 1:00 pm each day the system will take a reading and record the change in static pressure. The clean or replace filter message will pop up when the filter is full. Dec 21, 2020 · I have a three year old Carrier Infinity System Control Thermostat (SYSTXCCITC01-B) connected to a Carrier Furnace. The thermostat has stopped allowing me to use the schedule function. In addition, as far as I can tell, it has stopped allowing me to adjust the time. It does show the time which but it is off by one hour as it seems to think we ... Mar 7, 2019 · If you have a newer touch thermostat, in my case, circa 2017 SYSTXCCITC01-B (which retails for close to $1000, though can find cheaper on eBay like I did), you CAN NOT get this working with Home Assistant at this time. Infinitive will NOT work with this model thermostat. SYSTXCCITC01---B, SYSTXCCWIC01---B, SYSTXCCICF01---B, SYSTXCCWIF01---B Infinityr System Control Owner’s Manual A170203 A180218C NOTE: Read the entire instruction manual before starting the installation. The features and functions outlined in this Owner’s Manual reflect Version 1.3 or later software. Infinity ® System Control - SYSTXCCITC01-B. The Infinity ® System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface. With wireless connectivity, occupancy sensing capabilities and built-in smarts, the Infinity System Control puts you in command of comfort and energy ... • When you have completed all of the settings touch SAVE. 3.1.2. Setup Time Zone The time zone can be selected by selecting the set time zone from the menu. Then select the time zone for the location. Time zones for both US and Canada are included. 3.1.3. Enable Time Synchronization After setting up the time zone, the time synchronization can ...$99900 FREE Returns FREE delivery Saturday, September 9 Or fastest delivery Wednesday, September 6. Order within 22 hrs 54 mins Select delivery location Qty: 1 Buy Now Payment Secure transaction Ships from Amazon Sold by Returns Eligible for Return, Refund or Replacement within 30 days of receipt Support Product support included PaymentLooks like you have a 5 stage, or green speed unit. Your going to need a contractor. Sometimes I can have weird electrical harmonics throw a communication fault, and it will pass. Those codes back to back, mean: 1. You had an electrical problem in the outdoor unit. 2. The outdoor board is no longer operating for a myriad of reasons.CE - Carrier EnterpriseI've been looking to "upgrade" to the SYSTXCCITC01 thermostats to give remote access and smart home controls, but I am trying to determine what the difference between the A and B revisions are. The company that installed my Infinity system is quoting me to install the new thermostat, but list the A revision as the model.item 4 Carrier Infinity Touch Wi-Fi Thermostat System Control SYSTXCCITC01-B Carrier Infinity Touch Wi-Fi Thermostat System Control SYSTXCCITC01-B $499.99 0 bids 6d 21h item 5 Carrier Infinity Touch Control AC Thermostat SYSTXCCITN01-A Version 10 TESTED Carrier Infinity Touch Control AC Thermostat SYSTXCCITN01-A Version 10 TESTED Wi-Fi ® enabled smart thermostats give you control over your home comfort. Using iOS ® or Android ® devices, you can adjust temperature, humidity, airflow, and ventilation from anywhere in the world. Add features like SmartSensors, voice control with Alexa ®, streaming music, or even hands-free calling to further enhance your smart home ...Nov 29, 2018 · I've been looking to "upgrade" to the SYSTXCCITC01 thermostats to give remote access and smart home controls, but I am trying to determine what the difference between the A and B revisions are. The company that installed my Infinity system is quoting me to install the new thermostat, but list the A revision as the model. Details. Carrier’s 24VNA0 with Greenspeed® Intelligence is a variable speed cooling product providing up to 20.5 SEER cooling efficiency. Lower speed operation, when needed in cooling, for enhanced comfort and dehumidification. This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency when matched ... Carrier® Infinity® - SYSTXCCITC01-B System Control NOTE: Infinity® System Control compatible with Infinity® rated indoor equipment only. The Infinity® System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface. Carrier® Infinity® System Control (SYSTXCCITC01-B) Occupancy Sensing Sequence of Operation Page 6 ...SYSTXCCITC01-C The series C software is available by Over The Air (OTA) only. Note: This software is for the Series C controls only. The Series A or B controls cannot useMar 7, 2019 · If you have a newer touch thermostat, in my case, circa 2017 SYSTXCCITC01-B (which retails for close to $1000, though can find cheaper on eBay like I did), you CAN NOT get this working with Home Assistant at this time. Infinitive will NOT work with this model thermostat. Carrier thermostat won’t turn on. If your thermostat has a blank screen, it’s likely due to a power issue. Check your electrical box and reset the circuit breaker. If you have a fuse box and the fuse has blown, replace it. Check the switches connected to your thermostat, furnace, and air conditioner. If you can pinpoint the issue to a ...View and Download Carrier Infinity SYSTXCCWIC01-B installation instructions manual online. Infinity SYSTXCCWIC01-B thermostat pdf manual download. Also for: Infinity systxccitc01-b, Infinity systxccicf01-b, Infinity systxccwif01-b, A170203, A180218c.Carrier SYSTXCCITC01-B Installation Instructions. Rating 2.5 (votes: 4) Description. Wi-Fi ® enabled smart thermostats give you control over your home comfort. Using iOS ® or Android ® devices, you can adjust temperature, humidity, airflow, and ventilation from anywhere in the world. Add features like SmartSensors, voice control with Alexa ®, streaming music, or even hands-free calling to further enhance your smart home ... Carrier Infinity Touch circus continues SYSTXCCITC01-B off calibration issue. Ok, I have had my share of fun with Carrier infinity touch thermostats but I had a call back on a touch B where the temperature is off by 4 degrees. I verified temps and the unit is indeed showing 4 degrees colder than room temp.Carrier SYSTXCCITC01-B - Infinity System Control - 7 Day Programmable w/ Touch-N-Go- <b>Note: This item requires a "G" terminal that was not available on units prior to 2008 Infinity Models.</b><br><br> The Infinity® System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface. With wireless connectivity, occupancy ...The primary cause has been corrected; but additional analysis is in progress to ensure this will not happen in the future. Minor updates: False G-terminal Alerts could be triggered during learning process check, if the system control reads the status inputs from furnace and fancoil before they have been set properly. Dec 21, 2020 · I have a three year old Carrier Infinity System Control Thermostat (SYSTXCCITC01-B) connected to a Carrier Furnace. The thermostat has stopped allowing me to use the schedule function. In addition, as far as I can tell, it has stopped allowing me to adjust the time. It does show the time which but it is off by one hour as it seems to think we ... Hello Carrier Experts. I have a carrier infinity Model 58 MVP 120 with an infinity control. My furnace has been flashing code 25 for two years. I had a two seperate carrier technicians tell me don't w … read moreCarrier Infinity SYSTXCCITC01-B Touch Screen Programmable WiFi... › Customer reviews How customer reviews and ratings work Positive reviews L.A. Buyer in Granada hills It was an easy installation, this thermostat in only for the Carrier infinity system. Read more 12 people found this helpful Carrier Infinity Communicating Thermostat overviewCarrier® Infinity® System Control (SYSTXCCITC01-B) Occupancy Sensing Sequence of Operation Page 6 ... The primary cause has been corrected; but additional analysis is in progress to ensure this will not happen in the future. Minor updates: False G-terminal Alerts could be triggered during learning process check, if the system control reads the status inputs from furnace and fancoil before they have been set properly.Details. Carrier’s 24VNA0 with Greenspeed® Intelligence is a variable speed cooling product providing up to 20.5 SEER cooling efficiency. Lower speed operation, when needed in cooling, for enhanced comfort and dehumidification. This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency when matched ...Carrier® Infinity® - SYSTXCCITC01-B System Control NOTE: Infinity® System Control compatible with Infinity® rated indoor equipment only. The Infinity® System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface.I wish I had seen this sooner. The infinity thermostat has not been great for me. I have the fancy carrier infinity thermostat. It is not worth it. I hate the controls, or lack of controls really. The ability to use a variable fan speed is a lie. The system determines fan speed and mine has never been adjustable. You can set 4 temperatures. Apr 13, 2023 · The evaporator coil had been replace in 11/22 and this issue started 2/23 so i don’t thing anything could have caused a problem when the coil was replaced. When I ran the new wire to the infinity control and left off the Wi-Fi for 3-4 months the customer didn’t call with any issues or just ignored them. Carrier Côr ® Wi-Fi ® Thermostat - TP-WEM01-A. Your heating and cooling system is where you spend most of your energy dollars so saving on your utilities is important. The innovative Côr ® thermostat has been Energy Star ® certified and is designed to combine home comfort with reduced energy use; homeowners saved an average of 20% on their heating and cooling energy costs. Hello, just got a brand new carrier infinity installed and it came with an Infinity SYSTXCCITC01-C thermostat. I have been able to connect it to my WI-Fi network but I can’t seem to connect to the Infinity server. The touch screen shows a wi-fi icon with a hazard symbol. Dec 21, 2020 · I have a three year old Carrier Infinity System Control Thermostat (SYSTXCCITC01-B) connected to a Carrier Furnace. The thermostat has stopped allowing me to use the schedule function. In addition, as far as I can tell, it has stopped allowing me to adjust the time. It does show the time which but it is off by one hour as it seems to think we ... May 29, 2019 · I've learned it's better to ask first. Thanks very much for the reply! I can confirm that these controls are interchangeable. I've installed a Carrier Infinity Touch SYSTXCCITC01-B with a Carrier FE4AN Fan Coil and a Bryant 280ANV Heat Pump and they all get along just fine. Oct 6, 2020 · Hello I have a Carrier infinity syetem with a SYSTXCCITC01-B thermostat. I have been trying to figure out how to have the humidifier on in manual or fan only mode. I can get it to turn on in the cool and heat profiles but cant get it to come on when I just want the fan on without heat or cool. The reason I want this is because I dont need heat ... SYSTXCCITC01-B, SYSTXCCWIC01-B, SYSTXCCICF01-B, SYSTXCCWIF01-B ... The information displayed on the Home Screen will appear when there has been no interactionApr 5, 2023 · Carrier Infinity Touch circus continues SYSTXCCITC01-B off calibration issue. Ok, I have had my share of fun with Carrier infinity touch thermostats but I had a call back on a touch B where the temperature is off by 4 degrees. I verified temps and the unit is indeed showing 4 degrees colder than room temp. –Use the Up (Y) and Down (B) buttons to set the desired ventilation level. –Press SAVE when finished, or CANCEL to discard any changes. •If applicable, next select the amount of fresh air to circulate during cooling mode by touching COOLING FRESH AIR. Again, you will have the option of choosing among AUTO, MANUAL and OFF.You’re zero degrees of separation from the degree you want. Select a model below to learn more. Carrier Infinity® Series Controls System Control(SYSTXCCITC01-B) System Control(SYSTXCCWIC01-B) Côr® Thermostats Côr® Wi-Fi®(TP-WEM01-A) Côr® 7C Wi-Fi®(TSTWRH01) Côr® 5C Wi-Fi®(TSTWHA01) Côr® 7(TSTPRH01) Côr® 5(TSTPHA01) Carrier Performance™ Series Thermostats TP-PRH01-B TP-NRH01 ... Nov 29, 2018 · I've been looking to "upgrade" to the SYSTXCCITC01 thermostats to give remote access and smart home controls, but I am trying to determine what the difference between the A and B revisions are. The company that installed my Infinity system is quoting me to install the new thermostat, but list the A revision as the model. Carrier Infinity - SYSTXCCITC01-B System Control NOTE: Infinity System Control compatible with Infinity rated indoor equipment only. The Infinity System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface. $99900 FREE Returns FREE delivery Saturday, September 9 Or fastest delivery Wednesday, September 6. Order within 22 hrs 54 mins Select delivery location Qty: 1 Buy Now Payment Secure transaction Ships from Amazon Sold by Returns Eligible for Return, Refund or Replacement within 30 days of receipt Support Product support included PaymentThe primary cause has been corrected; but additional analysis is in progress to ensure this will not happen in the future. Minor updates: False G-terminal Alerts could be triggered during learning process check, if the system control reads the status inputs from furnace and fancoil before they have been set properly.SYSTXCCITC01-B, SYSTXCCWIC01-B, SYSTXCCICF01-B, SYSTXCCWIF01-B ... The information displayed on the Home Screen will appear when there has been no interactionI'm making a wild guess and the B variant of SYSTXCCITC01 line has different firmware than the A variant. So I decided to go find an A and I will have one a week. Assuming Infinitude starts coughing useful valid data by just swapping thermostats would be useful information. I wonder if anyone has 131493-12 .hex file for the A variant?That model has been discontinued for some time, they’ve supersedes it with the touchscreen infinity interfaces SYSTXCCITC01-B Coxwain007 • 8 mo. ago(Models: SYSTXCCITW01-A, SYSTXCCINTN01-A, SYSTXCCITC01-A, SYSTXCCITC01-B, SYSTXCCWIC01-B) Daikin (Models: Daikin One) Daikin/Honeywell (Models: CTKO4, THX9001R5029) Ecobee (Models: Ecobee 3 Lite, Ecobee 4, Ecobee 5, Ecobee 6 Enhanced, Ecobee 6 Prem ium) Honeywell Prestige (Models: Prestige IAQ, Wi-Fi 9000) Honeywell T6 ProSYSTXCCITC01---B, SYSTXCCWIC01---B, SYSTXCCICF01---B, SYSTXCCWIF01---B Infinityr System Control Owner’s Manual A170203 A180218C NOTE: Read the entire instruction manual before starting the installation. The features and functions outlined in this Owner’s Manual reflect Version 1.3 or later software. Nov 5, 2021 · I have a Carrier 58 MVB080-F-10114 furnace. I keep having issues with it tripping on the flame rollout switch. I have had a furnace company come and check it out twice and they haven't been able to te … read more If screen is blank we have lost power to the thermostat. Check breaker to indoor unit. Next, check near the indoor unit for a float switch in drain and if you have one lift it to see if we get power to thermostat. If that drain gets partially clogged the float will kill power to so it does not keep making water and ruin ceiling carpet or floor.To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals. Outdoor Unit Model: 25VNA048A00300. Indoor Unit Model: FE4ANB006. System Control Mode: SYSTXCCITC01-B. System Control Firmware Version: CESR131626-04.31. BTW, the problem with the outdoor unit is when it gets down to the low 20's at night it will start making a noise unlike defrost mode that NEVER stops.Ok you have a wiring issue between the unit and the thermostat. The RED wire is the 24 volt wire so that would be the one that is likely grounded somewhere. You could go to the store and get a new thermostat cable. Take a short whip and connect the new cable to the unit and the thermostat and see. If it works then your cable in the wall is bad ...Sep 1, 2019 · Carrier Infinity SYSTXCCITC01-B compatibility with older Infinity Systems. I have a circa 2007 Carrier Infinity System (communicating) and would like to know if I can upgrade to the SYSTXCCITC01-B wifi thermostats. My outside unit is the 24ANA7 and the furnace is the 58CVA110. I have the old SYSTXCCUID01-B communicating thermostat. T. The Raddish Discussion starter · Mar 18, 2012. I have a Carrier Infinity HVAC system, and this evening the thermostat lost power. I used my google prowess and found this, so this evening I crawled up in the attic and removed both panels. The 3 amp fuse is good, but there is an amber LED next to the fuse that is lit.Hello Carrier Experts. I have a carrier infinity Model 58 MVP 120 with an infinity control. My furnace has been flashing code 25 for two years. I had a two seperate carrier technicians tell me don't w … read moreNov 29, 2018 · I've been looking to "upgrade" to the SYSTXCCITC01 thermostats to give remote access and smart home controls, but I am trying to determine what the difference between the A and B revisions are. The company that installed my Infinity system is quoting me to install the new thermostat, but list the A revision as the model. Carrier Infinity - SYSTXCCITC01-B System Control NOTE: Infinity System Control compatible with Infinity rated indoor equipment only. The Infinity System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface. Côr ® Wi-Fi ® Thermostat - TP-WEM01-A. Your heating and cooling system is where you spend most of your energy dollars so saving on your utilities is important. The innovative Côr ® thermostat has been Energy Star ® certified and is designed to combine home comfort with reduced energy use; homeowners saved an average of 20% on their heating and cooling energy costs.Côr ® Wi-Fi ® Thermostat - TP-WEM01-A. Your heating and cooling system is where you spend most of your energy dollars so saving on your utilities is important. The innovative Côr ® thermostat has been Energy Star ® certified and is designed to combine home comfort with reduced energy use; homeowners saved an average of 20% on their heating and cooling energy costs. SYSTXCCITC01-C The series C software is available by Over The Air (OTA) only. Note: This software is for the Series C controls only. The Series A or B controls cannot useCarrier SYSTXCCSMS01-B - Infinity System Smart Sensor- Infinity System Smart Sensor. ... SYSTXCCSMS01-B has been discontinued. Discontinued May 21, 2021.The Carrier Infinity SYSTXCCITC01-B is part of the Thermostats test program at Consumer Reports. In our lab tests, Smart Thermostats models like the Infinity SYSTXCCITC01-B are rated... May 11, 2018 · I'm making a wild guess and the B variant of SYSTXCCITC01 line has different firmware than the A variant. So I decided to go find an A and I will have one a week. Assuming Infinitude starts coughing useful valid data by just swapping thermostats would be useful information. I wonder if anyone has 131493-12 .hex file for the A variant? Nov 11, 2022 · 8 Post Likes Carrier Thermostat SYSTXCCITC01-B vs SYSTXCCITC01-C Does anyone know the difference between these two models for Carrier's Infinity controlling thermostat? It seems that Carrier updated the model from B to C, but I do not see a chart or description anywhere of the differences between the two if any. Reply 11-11-2022, 07:02 PM #2 2sac Looks like you have a 5 stage, or green speed unit. Your going to need a contractor. Sometimes I can have weird electrical harmonics throw a communication fault, and it will pass. Those codes back to back, mean: 1. You had an electrical problem in the outdoor unit. 2. The outdoor board is no longer operating for a myriad of reasons.View and Download Carrier Infinity SYSTXCCWIC01-B installation instructions manual online. Infinity SYSTXCCWIC01-B thermostat pdf manual download. Also for: Infinity systxccitc01-b, Infinity systxccicf01-b, Infinity systxccwif01-b, A170203, A180218c. Carrier SYSTXCCITC01-B - Infinity System Control - 7 Day Programmable w/ Touch-N-Go- <b>Note: This item requires a "G" terminal that was not available on units prior to 2008 Infinity Models.</b><br><br> The Infinity® System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface. With wireless connectivity, occupancy ... Manuals and User Guides for Carrier Infinity SYSTXCCITC01-B. We have 4 Carrier Infinity SYSTXCCITC01-B manuals available for free PDF download: Installation Instructions Manual, Owner's Manual, Support Sheet.

I'm a newbie to this site. I've the latest Carrier Infinity WiFi thermostat SYSTXCCITC01-B installed in March of this year. I'm having trouble with connection to the Myinfinity server. My wifi connection is fine and it works with everything else in the house with the exception of the intermittent connection with the MyInfinity server.. John opercent27leary

systxccitc01 b has been discontinued

$99900 FREE Returns FREE delivery Saturday, September 9 Or fastest delivery Wednesday, September 6. Order within 22 hrs 54 mins Select delivery location Qty: 1 Buy Now Payment Secure transaction Ships from Amazon Sold by Returns Eligible for Return, Refund or Replacement within 30 days of receipt Support Product support included PaymentCarrier SYSTXCCITC01-B - Infinity System Control - 7 Day Programmable w/ Touch-N-Go- <b>Note: This item requires a "G" terminal that was not available on units prior to 2008 Infinity Models.</b><br><br> The Infinity® System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface. With wireless connectivity, occupancy ...Oct 31, 2018 · Our ten year-old Infinity SYSTXCC Controller (for running a dual stage Heat Pump/Furnace system) has failed, and according to our service guy, it cannot be repaired. In 2008 when we bought it, the warranty was a measly 5 years with no option to extend it via registration. Carrier won't do anything for us, so we're SOL. Carrier Côr ® Wi-Fi ® Thermostat - TP-WEM01-A. Your heating and cooling system is where you spend most of your energy dollars so saving on your utilities is important. The innovative Côr ® thermostat has been Energy Star ® certified and is designed to combine home comfort with reduced energy use; homeowners saved an average of 20% on their heating and cooling energy costs. Infinity System Compatible Designed exclusively for our Infinity ® system products. This control is required to utilize all features of an Infinity system. Energy-Saving Intelligence Provides real-time energy use tracking. The system will also automatically and continuously adjust itself for advanced energy-savings performance. Remote AccessYour Savings: $1,479.88 (52%) Carrier Products SYSTXCCITC01-B Infinity WiFi Touch Screen *** This Item is a direct current replacement for SYSTXCCUID01, SYSTXCCUID01-A, SYSTXCCUIZ01B, SYSTXCCUID01-V *** *** Factory New, Original Equipment OEM Carrier Products, Factory Warranty ***. Availability: Qty. 6 in stock for immediate shipment. Cr Wi-Fi Thermostat - TP-WEM01-A. Your heating and cooling system is where you spend most of your energy dollars so saving on your utilities is important. The innovative Cr thermostat has been Energy Star certified and is designed to combine home comfort with reduced energy use; homeowners saved an average of 20% on their heating and cooling energy costs.Ok you have a wiring issue between the unit and the thermostat. The RED wire is the 24 volt wire so that would be the one that is likely grounded somewhere. You could go to the store and get a new thermostat cable. Take a short whip and connect the new cable to the unit and the thermostat and see. If it works then your cable in the wall is bad ...item 4 Carrier Infinity Touch Wi-Fi Thermostat System Control SYSTXCCITC01-B Carrier Infinity Touch Wi-Fi Thermostat System Control SYSTXCCITC01-B $499.99 0 bids 6d 21h item 5 Carrier Infinity Touch Control AC Thermostat SYSTXCCITN01-A Version 10 TESTED Carrier Infinity Touch Control AC Thermostat SYSTXCCITN01-A Version 10 TESTEDCôr ® Wi-Fi ® Thermostat - TP-WEM01-A. Your heating and cooling system is where you spend most of your energy dollars so saving on your utilities is important. The innovative Côr ® thermostat has been Energy Star ® certified and is designed to combine home comfort with reduced energy use; homeowners saved an average of 20% on their heating and cooling energy costs. Hello Carrier Experts. I have a carrier infinity Model 58 MVP 120 with an infinity control. My furnace has been flashing code 25 for two years. I had a two seperate carrier technicians tell me don't w … read moreCopyright © Thermostat Manuals, 2020-2023. All rights belong to their respective owners Contact Information | Privacy Policy | Privacy PolicySYSTXCCITC01-C The series C software is available by Over The Air (OTA) only. Note: This software is for the Series C controls only. The Series A or B controls cannot use.

Popular Topics